An independent public resourceEnglish Español

City of Pflugerville

Published drinking-water records and contacts for City of Pflugerville. System TX2270014. Review sources and dates; not a real-time water assessment.

System ID
TX2270014
State or territory
TX
Published population served
63464
System type (source code)
CWS

Published records and dates

Missing records here do not mean the provider did not test. Published records are not a real-time assessment of your tap water.

Published testing results

Selected recent records are shown below. Different sampling locations and dates are not interchangeable. These excerpts are not a complete testing history.

“<” means below the stated reporting limit, not zero. A reported measurement alone is not a safety verdict. Read an example

EPA UCMR 5 — most recent imported sample per substance
SubstancePublished resultReporting limitSample dateSampling location
11Cl-PF3OUdS< 0.005 µg/L0.005 µg/L2025-12-01Surface Water Treatment Plant / EP007
4:2 FTS< 0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
6:2 FTS< 0.005 µg/L0.005 µg/L2025-12-01Surface Water Treatment Plant / EP007
8:2 FTS< 0.005 µg/L0.005 µg/L2025-12-01Surface Water Treatment Plant / EP007
9Cl-PF3ONS< 0.002 µg/L0.002 µg/L2025-12-01Surface Water Treatment Plant / EP007
ADONA< 0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
HFPO-DA< 0.005 µg/L0.005 µg/L2025-12-01Surface Water Treatment Plant / EP007
NEtFOSAA< 0.005 µg/L0.005 µg/L2025-12-01Surface Water Treatment Plant / EP007
NFDHA< 0.02 µg/L0.02 µg/L2025-12-01Surface Water Treatment Plant / EP007
NMeFOSAA< 0.006 µg/L0.006 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFBA0.0059 µg/L0.005 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFBS< 0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFDA< 0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFDoA< 0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFEESA< 0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFHpA< 0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFHpS< 0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFHxA< 0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFHxS0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFMBA< 0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFMPA< 0.004 µg/L0.004 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFNA< 0.004 µg/L0.004 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFOA< 0.004 µg/L0.004 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFOS< 0.004 µg/L0.004 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFPeA< 0.003 µg/L0.003 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFPeS< 0.004 µg/L0.004 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFTA< 0.008 µg/L0.008 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFTrDA< 0.007 µg/L0.007 µg/L2025-12-01Surface Water Treatment Plant / EP007
PFUnA< 0.002 µg/L0.002 µg/L2025-12-01Surface Water Treatment Plant / EP007
lithium10.3 µg/L9 µg/L2025-12-01Surface Water Treatment Plant / EP007

Download all EPA UCMR 5 records (CSV)

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0.0011 mg/L2023-01-01 – 2025-12-312026Q3
Lead (PB90) 0.00156 mg/L2022-07-01 – 2022-12-312026Q3
Lead (PB90) 0.00185 mg/L2022-01-01 – 2022-06-302026Q3
Lead (PB90) 0.00254 mg/L2019-01-01 – 2021-12-312026Q3
Lead (PB90) 0.00261 mg/L2018-01-01 – 2018-12-312026Q3
Lead (PB90) 0.00373 mg/L2017-07-01 – 2017-12-312026Q3
Lead (PB90) 0.00222 mg/L2017-01-01 – 2017-06-302026Q3
Lead (PB90) 0.00259 mg/L2014-01-01 – 2016-12-312026Q3

Published compliance history

68 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Twenty most recent imported compliance records
Rule / recordPeriodRecorded statusHealth-based (EPA classification)Source quarter
Long Term 2 Enhanced Surface Water Treatment Rule / Monitoring of Treatment (SWTR-Filter)2026-03-01 – 2026-03-31ResolvedNo2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2025-07-01 – 2025-09-30ResolvedYes2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2025-04-01 – 2025-06-30ResolvedYes2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2024-10-01 – 2024-12-31ResolvedYes2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2024-06-01 – 2024-06-30ResolvedNo2026Q3
Long Term 2 Enhanced Surface Water Treatment Rule / Treatment Technique (SWTR and GWR)2019-12-01 – 2019-12-31ResolvedYes2026Q3
Long Term 2 Enhanced Surface Water Treatment Rule / Monitoring of Treatment (SWTR-Filter)2019-10-01 – 2019-10-31ResolvedNo2026Q3
Long Term 2 Enhanced Surface Water Treatment Rule / Treatment Technique (SWTR and GWR)2019-09-01 – 2019-09-30ResolvedYes2026Q3
Interim and Long Term 1 Enhanced Surface Water Treatment Rule / Monitoring, Turbidity (Enhanced SWTR)2019-09-01 – 2019-09-30ResolvedNo2026Q3
Long Term 2 Enhanced Surface Water Treatment Rule / Monitoring of Treatment (SWTR-Filter)2019-09-01 – 2019-09-30ResolvedNo2026Q3
Surface Water Treatment Rule / Monitoring of Treatment (SWTR-Filter)2019-09-01 – 2019-09-30ResolvedNo2026Q3
Long Term 2 Enhanced Surface Water Treatment Rule / Treatment Technique (SWTR and GWR)2019-08-01 – 2019-08-31ResolvedYes2026Q3
Interim and Long Term 1 Enhanced Surface Water Treatment Rule / Monitoring, Turbidity (Enhanced SWTR)2019-08-01 – 2019-08-31ResolvedNo2026Q3
Long Term 2 Enhanced Surface Water Treatment Rule / Monitoring of Treatment (SWTR-Filter)2019-08-01 – 2019-08-31ResolvedNo2026Q3
Surface Water Treatment Rule / Monitoring of Treatment (SWTR-Filter)2019-08-01 – 2019-08-31ResolvedNo2026Q3
Long Term 2 Enhanced Surface Water Treatment Rule / Treatment Technique (SWTR and GWR)2019-07-01 – 2019-07-31ResolvedYes2026Q3
Interim and Long Term 1 Enhanced Surface Water Treatment Rule / Monitoring, Turbidity (Enhanced SWTR)2019-07-01 – 2019-07-31ResolvedNo2026Q3
Long Term 2 Enhanced Surface Water Treatment Rule / Monitoring of Treatment (SWTR-Filter)2019-07-01 – 2019-07-31ResolvedNo2026Q3
Surface Water Treatment Rule / Monitoring of Treatment (SWTR-Filter)2019-07-01 – 2019-07-31ResolvedNo2026Q3
Long Term 2 Enhanced Surface Water Treatment Rule / Treatment Technique (SWTR and GWR)2019-06-01 – 2019-06-30ResolvedYes2026Q3

Source dates and refresh checks

A refresh check is not a sample date. Publication periods, sample dates and checks are shown separately.

Administrative contact (EPA filing)

Gonzales, Victor: 512-990-6101

An administrative filing contact may not be a customer-service line. Confirm current contact details with the provider.

Official state resources · How to read these records