An independent public resourceEnglish Español

Yancey Wsc

Published drinking-water records and contacts for Yancey Wsc. System TX1630021. Review sources and dates; not a real-time water assessment.

System ID
TX1630021
State or territory
TX
Published population served
12186
System type (source code)
CWS

Published records and dates

Missing records here do not mean the provider did not test. Published records are not a real-time assessment of your tap water.

Published testing results

Selected recent records are shown below. Different sampling locations and dates are not interchangeable. These excerpts are not a complete testing history.

“<” means below the stated reporting limit, not zero. A reported measurement alone is not a safety verdict. Read an example

EPA UCMR 5 — most recent imported sample per substance
SubstancePublished resultReporting limitSample dateSampling location
11Cl-PF3OUdS< 0.005 µg/L0.005 µg/L2023-12-20YANCEY WSC / TRTTAP
4:2 FTS< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
6:2 FTS< 0.005 µg/L0.005 µg/L2023-12-20YANCEY WSC / TRTTAP
8:2 FTS< 0.005 µg/L0.005 µg/L2023-12-20YANCEY WSC / TRTTAP
9Cl-PF3ONS< 0.002 µg/L0.002 µg/L2023-12-20YANCEY WSC / TRTTAP
ADONA< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
HFPO-DA< 0.005 µg/L0.005 µg/L2023-12-20YANCEY WSC / TRTTAP
NEtFOSAA< 0.005 µg/L0.005 µg/L2023-12-20YANCEY WSC / TRTTAP
NFDHA< 0.02 µg/L0.02 µg/L2023-12-20YANCEY WSC / TRTTAP
NMeFOSAA< 0.006 µg/L0.006 µg/L2023-12-20YANCEY WSC / TRTTAP
PFBA< 0.005 µg/L0.005 µg/L2023-12-20YANCEY WSC / TRTTAP
PFBS< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
PFDA< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
PFDoA< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
PFEESA< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
PFHpA< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
PFHpS< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
PFHxA< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
PFHxS< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
PFMBA< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
PFMPA< 0.004 µg/L0.004 µg/L2023-12-20YANCEY WSC / TRTTAP
PFNA< 0.004 µg/L0.004 µg/L2023-12-20YANCEY WSC / TRTTAP
PFOA< 0.004 µg/L0.004 µg/L2023-12-20YANCEY WSC / TRTTAP
PFOS< 0.004 µg/L0.004 µg/L2023-12-20YANCEY WSC / TRTTAP
PFPeA< 0.003 µg/L0.003 µg/L2023-12-20YANCEY WSC / TRTTAP
PFPeS< 0.004 µg/L0.004 µg/L2023-12-20YANCEY WSC / TRTTAP
PFTA< 0.008 µg/L0.008 µg/L2023-12-20YANCEY WSC / TRTTAP
PFTrDA< 0.007 µg/L0.007 µg/L2023-12-20YANCEY WSC / TRTTAP
PFUnA< 0.002 µg/L0.002 µg/L2023-12-20YANCEY WSC / TRTTAP
lithium< 9 µg/L9 µg/L2023-12-20YANCEY WSC / TRTTAP

Download all EPA UCMR 5 records (CSV)

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0.0035 mg/L2023-01-01 – 2025-12-312026Q3
Lead (PB90) 0.0021 mg/L2020-01-01 – 2022-12-312026Q3
Lead (PB90) 0.0021 mg/L2017-01-01 – 2019-12-312026Q3
Lead (PB90) 0.0015 mg/L2014-01-01 – 2016-12-312026Q3
Lead (PB90) 0.00223 mg/L2011-01-01 – 2013-12-312026Q3
Lead (PB90) 0.00353 mg/L2008-01-01 – 2010-12-312026Q3
Lead (PB90) 0.00353 mg/L2008-01-01 – 2010-12-312026Q3
Lead (PB90) 0.0052 mg/L2005-01-01 – 2007-12-312026Q3

Published compliance history

3 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Twenty most recent imported compliance records
Rule / recordPeriodRecorded statusHealth-based (EPA classification)Source quarter
Lead and Copper Rule / Initial Tap Sampling for Pb and Cu1992-07-01 – 1993-06-30ArchivedNo2026Q3
Total Coliform Rule / Monitoring, Routine Minor (TCR)1992-02-01 – 1992-02-29ArchivedNo2026Q3
Total Coliform Rule / Notification, Public1992-02-01 – 1992-02-29ArchivedNo2026Q3

Source dates and refresh checks

A refresh check is not a sample date. Publication periods, sample dates and checks are shown separately.

Administrative contact (EPA filing)

Kauffman, Frankie: 830-741-5264

An administrative filing contact may not be a customer-service line. Confirm current contact details with the provider.

Official state resources · How to read these records