An independent public resourceEnglish Español

Yorktown Consold. Water Dist.#1

Published drinking-water records and contacts for Yorktown Consold. Water Dist.#1. System NY5903469. Review sources and dates; not a real-time water assessment.

System ID
NY5903469
State or territory
NY
Published population served
36000
System type (source code)
CWS

Published records and dates

Missing records here do not mean the provider did not test. Published records are not a real-time assessment of your tap water.

Published testing results

Selected recent records are shown below. Different sampling locations and dates are not interchangeable. These excerpts are not a complete testing history.

“<” means below the stated reporting limit, not zero. A reported measurement alone is not a safety verdict. Read an example

EPA UCMR 5 — most recent imported sample per substance
SubstancePublished resultReporting limitSample dateSampling location
11Cl-PF3OUdS< 0.005 µg/L0.005 µg/L2024-10-08Westchester County Water Intertie / 31727
4:2 FTS< 0.003 µg/L0.003 µg/L2024-10-08Northern Westchester Water Intertie / EP001
6:2 FTS< 0.005 µg/L0.005 µg/L2024-10-08Northern Westchester Water Intertie / EP001
8:2 FTS< 0.005 µg/L0.005 µg/L2024-10-08Westchester County Water Intertie / 31727
9Cl-PF3ONS< 0.002 µg/L0.002 µg/L2024-10-08Westchester County Water Intertie / 31727
ADONA< 0.003 µg/L0.003 µg/L2024-10-08Northern Westchester Water Intertie / EP001
HFPO-DA< 0.005 µg/L0.005 µg/L2024-10-08Northern Westchester Water Intertie / EP001
NEtFOSAA< 0.005 µg/L0.005 µg/L2024-10-08Westchester County Water Intertie / 31727
NFDHA< 0.02 µg/L0.02 µg/L2024-10-08Northern Westchester Water Intertie / EP001
NMeFOSAA< 0.006 µg/L0.006 µg/L2024-10-08Westchester County Water Intertie / 31727
PFBA< 0.005 µg/L0.005 µg/L2024-10-08Northern Westchester Water Intertie / EP001
PFBS< 0.003 µg/L0.003 µg/L2024-10-08Westchester County Water Intertie / 31727
PFDA< 0.003 µg/L0.003 µg/L2024-10-08Westchester County Water Intertie / 31727
PFDoA< 0.003 µg/L0.003 µg/L2024-10-08Northern Westchester Water Intertie / EP001
PFEESA< 0.003 µg/L0.003 µg/L2024-10-08Westchester County Water Intertie / 31727
PFHpA< 0.003 µg/L0.003 µg/L2024-10-08Northern Westchester Water Intertie / EP001
PFHpS< 0.003 µg/L0.003 µg/L2024-10-08Northern Westchester Water Intertie / EP001
PFHxA< 0.003 µg/L0.003 µg/L2024-10-08Westchester County Water Intertie / 31727
PFHxS< 0.003 µg/L0.003 µg/L2024-10-08Northern Westchester Water Intertie / EP001
PFMBA< 0.003 µg/L0.003 µg/L2024-10-08Northern Westchester Water Intertie / EP001
PFMPA< 0.004 µg/L0.004 µg/L2024-10-08Northern Westchester Water Intertie / EP001
PFNA< 0.004 µg/L0.004 µg/L2024-10-08Northern Westchester Water Intertie / EP001
PFOA0.0060 µg/L0.004 µg/L2024-10-08Westchester County Water Intertie / 31727
PFOS< 0.004 µg/L0.004 µg/L2024-10-08Westchester County Water Intertie / 31727
PFPeA0.0030 µg/L0.003 µg/L2024-10-08Westchester County Water Intertie / 31727
PFPeS< 0.004 µg/L0.004 µg/L2024-10-08Westchester County Water Intertie / 31727
PFTA< 0.008 µg/L0.008 µg/L2024-10-08Northern Westchester Water Intertie / EP001
PFTrDA< 0.007 µg/L0.007 µg/L2024-10-08Westchester County Water Intertie / 31727
PFUnA< 0.002 µg/L0.002 µg/L2024-10-08Westchester County Water Intertie / 31727
lithium< 9 µg/L9 µg/L2024-10-08Westchester County Water Intertie / 31727

Download all EPA UCMR 5 records (CSV)

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0.0012 mg/L2023-01-01 – 2025-12-312026Q3
Lead (PB90) 0.001 mg/L2020-01-01 – 2022-12-312026Q3
Lead (PB90) 0.0027 mg/L2017-01-01 – 2019-12-312026Q3
Lead (PB90) 0.0022 mg/L2014-01-01 – 2016-12-312026Q3
Lead (PB90) 0.002 mg/L2011-01-01 – 2013-12-312026Q3
Lead (PB90) 0.001 mg/L2008-01-01 – 2010-12-312026Q3
Lead (PB90) 0.0047 mg/L2005-01-01 – 2007-12-312026Q3
Lead (PB90) 0.0063 mg/L2002-01-01 – 2004-12-312026Q3

Published compliance history

10 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Twenty most recent imported compliance records
Rule / recordPeriodRecorded statusHealth-based (EPA classification)Source quarter
Lead and Copper Rule Revisions / LSL Reporting2024-10-17 – —ResolvedNo2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2021-01-01 – 2021-03-31ResolvedYes2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2020-10-01 – 2020-12-31ResolvedYes2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2020-07-01 – 2020-09-30ResolvedYes2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2020-04-01 – 2020-06-30ResolvedYes2026Q3
Revised Total Coliform Rule / Monitoring, Additional Routine (RTCR)2018-11-01 – 2018-11-30ResolvedNo2026Q3
Lead and Copper Rule / Follow-up Or Routine LCR Tap M/R2018-01-01 – —ResolvedNo2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Monthly (TCR)1995-07-01 – 1995-07-31ArchivedYes2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Monthly (TCR)1993-07-01 – 1993-07-31ArchivedYes2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Monthly (TCR)1993-07-01 – 1993-07-31ArchivedYes2026Q3

Source dates and refresh checks

A refresh check is not a sample date. Publication periods, sample dates and checks are shown separately.

Administrative contact (EPA filing)

Lachterman, Edward: 914-962-5722

An administrative filing contact may not be a customer-service line. Confirm current contact details with the provider.

Official state resources · How to read these records