An independent public resourceEnglish Español

Winchester Water Dept

Published drinking-water records and contacts for Winchester Water Dept. System MA3344000. Review sources and dates; not a real-time water assessment.

System ID
MA3344000
State or territory
MA
Published population served
22970
System type (source code)
CWS

Published records and dates

Missing records here do not mean the provider did not test. Published records are not a real-time assessment of your tap water.

Read the provider’s annual water quality report

Report link listed: 2026-10-09. This is not the report’s sampling date.

Published testing results

Selected recent records are shown below. Different sampling locations and dates are not interchangeable. These excerpts are not a complete testing history.

“<” means below the stated reporting limit, not zero. A reported measurement alone is not a safety verdict. Read an example

EPA UCMR 5 — most recent imported sample per substance
SubstancePublished resultReporting limitSample dateSampling location
11Cl-PF3OUdS< 0.005 µg/L0.005 µg/L2025-01-07MWRA Intertie / 10344
4:2 FTS< 0.003 µg/L0.003 µg/L2025-01-07WTP / 10342
6:2 FTS< 0.005 µg/L0.005 µg/L2025-01-07WTP / 10342
8:2 FTS< 0.005 µg/L0.005 µg/L2025-01-07MWRA Intertie / 10344
9Cl-PF3ONS< 0.002 µg/L0.002 µg/L2025-01-07MWRA Intertie / 10344
ADONA< 0.003 µg/L0.003 µg/L2025-01-07MWRA Intertie / 10344
HFPO-DA< 0.005 µg/L0.005 µg/L2025-01-07MWRA Intertie / 10344
NEtFOSAA< 0.005 µg/L0.005 µg/L2025-01-07WTP / 10342
NFDHA< 0.02 µg/L0.02 µg/L2025-01-07MWRA Intertie / 10344
NMeFOSAA< 0.006 µg/L0.006 µg/L2025-01-07WTP / 10342
PFBA< 0.005 µg/L0.005 µg/L2025-01-07WTP / 10342
PFBS< 0.003 µg/L0.003 µg/L2025-01-07WTP / 10342
PFDA< 0.003 µg/L0.003 µg/L2025-01-07WTP / 10342
PFDoA< 0.003 µg/L0.003 µg/L2025-01-07MWRA Intertie / 10344
PFEESA< 0.003 µg/L0.003 µg/L2025-01-07MWRA Intertie / 10344
PFHpA< 0.003 µg/L0.003 µg/L2025-01-07MWRA Intertie / 10344
PFHpS< 0.003 µg/L0.003 µg/L2025-01-07MWRA Intertie / 10344
PFHxA< 0.003 µg/L0.003 µg/L2025-01-07MWRA Intertie / 10344
PFHxS< 0.003 µg/L0.003 µg/L2025-01-07MWRA Intertie / 10344
PFMBA< 0.003 µg/L0.003 µg/L2025-01-07WTP / 10342
PFMPA< 0.004 µg/L0.004 µg/L2025-01-07MWRA Intertie / 10344
PFNA< 0.004 µg/L0.004 µg/L2025-01-07MWRA Intertie / 10344
PFOA< 0.004 µg/L0.004 µg/L2025-01-07WTP / 10342
PFOS< 0.004 µg/L0.004 µg/L2025-01-07MWRA Intertie / 10344
PFPeA< 0.003 µg/L0.003 µg/L2025-01-07MWRA Intertie / 10344
PFPeS< 0.004 µg/L0.004 µg/L2025-01-07MWRA Intertie / 10344
PFTA< 0.008 µg/L0.008 µg/L2025-01-07WTP / 10342
PFTrDA< 0.007 µg/L0.007 µg/L2025-01-07MWRA Intertie / 10344
PFUnA< 0.002 µg/L0.002 µg/L2025-01-07WTP / 10342
lithium< 9 µg/L9 µg/L2025-01-07WTP / 10342

Download all EPA UCMR 5 records (CSV)

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0.0029 mg/L2024-01-01 – 2026-12-312026Q3
Lead (PB90) 0.0042 mg/L2021-01-01 – 2023-12-312026Q3
Lead (PB90) 0.0059 mg/L2018-01-01 – 2020-12-312026Q3
Lead (PB90) 0.007 mg/L2015-01-01 – 2017-12-312026Q3
Lead (PB90) 0.005 mg/L2012-01-01 – 2014-12-312026Q3
Lead (PB90) 0.007 mg/L2011-01-01 – 2011-12-312026Q3
Lead (PB90) 0.004 mg/L2008-01-01 – 2008-12-312026Q3
Lead (PB90) 0.0134 mg/L2005-01-01 – 2005-12-312026Q3
Twelve most recent imported state laboratory records
SubstancePublished resultSample dateLocation / source
N-METHYL PERFLUOROOCTANESULFONAMIDOACETIC ACID - NMEFOSAABelow a limit; numeric threshold unavailable ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results
PERFLUOROTRIDECANOIC ACID - PFTRDABelow a limit; numeric threshold unavailable ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results
9-CHLOROHEXADECAFLUORO-3-OXANONE-1-SULFONIC ACID-9CL-PF3ONSBelow a limit; numeric threshold unavailable ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results
4,8-DIOXA-3H-PERFLUORONONANOIC ACID - ADONABelow a limit; numeric threshold unavailable ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results
PERFLUORONONANOIC ACID-PFNA0.47 J ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results
PERFLUOROUNDECANOIC ACID - PFUNABelow a limit; numeric threshold unavailable ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results
HEXAFLUOROPROPYLENE OXIDE DIMER ACID - HFPO-DABelow a limit; numeric threshold unavailable ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results
PERFLUOROTETRADECANOIC ACID - PFTABelow a limit; numeric threshold unavailable ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results
PERFLUOROBUTANESULFONIC ACID-PFBS0.47 J ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results
11-CHLOROEICOSAFLUORO-3-OXAUNDECANE-1-SULFONIC ACID-11CL-PF3OUDSBelow a limit; numeric threshold unavailable ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results
PERFLUOROOCTANOIC ACID-PFOA1.6 J ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results
PERFLUOROHEXANOIC ACID - PFHXA0.84 J ng/L2026-07-07WTP- FINISHED WATER / Massachusetts EEA PFAS monitoring results

State sampling points can include untreated water. Publisher qualifiers and units are retained; consult the full source notes before interpreting a record.

Download state records with source notes (CSV)

Published compliance history

21 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Twenty most recent imported compliance records
Rule / recordPeriodRecorded statusHealth-based (EPA classification)Source quarter
Inorganic Chemicals / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Arsenic Rule / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Inorganic Chemicals / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Inorganic Chemicals / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Inorganic Chemicals / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Inorganic Chemicals / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Inorganic Chemicals / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Inorganic Chemicals / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Inorganic Chemicals / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Inorganic Chemicals / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Inorganic Chemicals / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Inorganic Chemicals / Monitoring, Regular2026-01-01 – 2026-03-31ArchivedNo2026Q3
Radionuclides and Revised Rad Rule / Monitoring, Regular1997-07-01 – 1997-09-30ArchivedNo2026Q3
Radionuclides and Revised Rad Rule / Monitoring, Regular1997-07-01 – 1997-09-30ArchivedNo2026Q3
Radionuclides and Revised Rad Rule / Monitoring, Regular1997-07-01 – 1997-09-30ArchivedNo2026Q3
Radionuclides and Revised Rad Rule / Monitoring, Regular1997-07-01 – 1997-09-30ArchivedNo2026Q3
Radionuclides and Revised Rad Rule / Monitoring, Regular1997-07-01 – 1997-09-30ArchivedNo2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Monthly (TCR)1997-06-01 – 1997-06-30ArchivedYes2026Q3
Nitrate Rule / Monitoring, Regular1997-01-01 – 1997-03-31ArchivedNo2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Monthly (TCR)1996-04-01 – 1996-04-30ArchivedYes2026Q3

Source dates and refresh checks

A refresh check is not a sample date. Publication periods, sample dates and checks are shown separately.

Administrative contact (EPA filing)

Winchester Water Dept: 7817217100

An administrative filing contact may not be a customer-service line. Confirm current contact details with the provider.

Official state resources · How to read these records