An independent public resourceEnglish Español

Best Friends Animal Society

Published drinking-water records and contacts for Best Friends Animal Society. System UTAH13049. Review sources and dates; not a real-time water assessment.

System ID
UTAH13049
State or territory
UT
Published population served
47
System type (source code)
CWS

Published records and dates

Missing records here do not mean the provider did not test. Published records are not a real-time assessment of your tap water.

Published testing results

Selected recent records are shown below. Different sampling locations and dates are not interchangeable. These excerpts are not a complete testing history.

“<” means below the stated reporting limit, not zero. A reported measurement alone is not a safety verdict. Read an example

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0.0009 mg/L2023-01-01 – 2025-12-312026Q3
Lead (PB90) 0.0004 mg/L2014-01-01 – 2016-12-312026Q3
Lead (PB90) 0.0019 mg/L2011-01-01 – 2013-12-312026Q3
Lead (PB90) 0.0019 mg/L2011-01-01 – 2013-12-312026Q3
Lead (PB90) 0.0015 mg/L2008-01-01 – 2010-12-312026Q3
Lead (PB90) 0.001 mg/L2005-01-01 – 2007-12-312026Q3
Lead (PB90) 0.005 mg/L2004-01-01 – 2006-12-312026Q3
Lead (PB90) 0.005 mg/L2002-01-01 – 2004-12-312026Q3
Twelve most recent imported state laboratory records
SubstancePublished resultSample dateLocation / source
4:2 FTS< 0.4 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling
PFHpS< 0.6 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling
PFPeA< 0.5 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling
PFEESA< 0.5 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling
PFMBA< 0.4 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling
8:2 FTS< 0.5 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling
F53B-Minor< 0.7 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling
PFOA< 0.7 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling
PFDA< 0.5 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling
PFMPA< 0.4 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling
PFBA< 1 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling
NFDHA< 0.5 ppt2025-10-06GROUPED SOURCE SAMPLING STATION / Utah DEQ PFAS sampling

State sampling points can include untreated water. Publisher qualifiers and units are retained; consult the full source notes before interpreting a record.

Download state records with source notes (CSV)

Published compliance history

11 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Twenty most recent imported compliance records
Rule / recordPeriodRecorded statusHealth-based (EPA classification)Source quarter
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2020-06-01 – 2020-06-30ResolvedNo2026Q3
Revised Total Coliform Rule / Sample Siting Plan Errors (RTCR)2017-10-01 – —ResolvedNo2026Q3
Total Coliform Rule / Notification, Public2000-02-01 – 2000-02-29ArchivedNo2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Monthly (TCR)2000-02-01 – 2000-02-29ArchivedYes2026Q3
Total Coliform Rule / Notification, Public2000-01-01 – 2000-01-31ArchivedNo2026Q3
Total Coliform Rule / Monitoring, Routine Major (TCR)2000-01-01 – 2000-01-31ArchivedNo2026Q3
Total Coliform Rule / Notification, Public1999-12-01 – 1999-12-31ArchivedNo2026Q3
Total Coliform Rule / Notification, Public1999-04-01 – 1999-06-30ArchivedNo2026Q3
Total Coliform Rule / Monitoring, Routine Major (TCR)1999-04-01 – 1999-06-30ArchivedNo2026Q3
Total Coliform Rule / Monitoring, Routine Major (TCR)1998-04-01 – 1998-06-30ArchivedNo2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Monthly (TCR)1998-01-01 – 1998-01-31ArchivedYes2026Q3

Source dates and refresh checks

A refresh check is not a sample date. Publication periods, sample dates and checks are shown separately.

Administrative contact (EPA filing)

Brinkerhoff, Jarad Judd: 435-274-7522

An administrative filing contact may not be a customer-service line. Confirm current contact details with the provider.

Official state resources · How to read these records