An independent public resourceEnglish Español

Wilson Co Water & Wastewater

Published drinking-water records and contacts for Wilson Co Water & Wastewater. System TN0000790. Review sources and dates; not a real-time water assessment.

System ID
TN0000790
State or territory
TN
Published population served
22680
System type (source code)
CWS

Published records and dates

Missing records here do not mean the provider did not test. Published records are not a real-time assessment of your tap water.

Published testing results

Selected recent records are shown below. Different sampling locations and dates are not interchangeable. These excerpts are not a complete testing history.

“<” means below the stated reporting limit, not zero. A reported measurement alone is not a safety verdict. Read an example

EPA UCMR 5 — most recent imported sample per substance
SubstancePublished resultReporting limitSample dateSampling location
11Cl-PF3OUdS< 0.005 µg/L0.005 µg/L2025-09-23Lebanon Connection / CC01
4:2 FTS< 0.003 µg/L0.003 µg/L2025-09-23DeKalb UD #1 Connection / CC04
6:2 FTS< 0.005 µg/L0.005 µg/L2025-09-23Gladeville Connection / CC02
8:2 FTS< 0.005 µg/L0.005 µg/L2025-09-23Lebanon Connection / CC01
9Cl-PF3ONS< 0.002 µg/L0.002 µg/L2025-09-23Gladeville Connection / CC02
ADONA< 0.003 µg/L0.003 µg/L2025-09-23DeKalb UD #1 Connection / CC04
HFPO-DA< 0.005 µg/L0.005 µg/L2025-09-23DeKalb UD #1 Connection / CC04
NEtFOSAA< 0.005 µg/L0.005 µg/L2025-09-23DeKalb UD #1 Connection / CC04
NFDHA< 0.02 µg/L0.02 µg/L2025-09-23DeKalb UD #1 Connection / CC04
NMeFOSAA< 0.006 µg/L0.006 µg/L2025-09-23Gladeville Connection / CC02
PFBA< 0.005 µg/L0.005 µg/L2025-09-23Lebanon Connection / CC01
PFBS< 0.003 µg/L0.003 µg/L2025-09-23DeKalb UD #1 Connection / CC04
PFDA< 0.003 µg/L0.003 µg/L2025-09-23Gladeville Connection / CC02
PFDoA< 0.003 µg/L0.003 µg/L2025-09-23Consolidated UD Connection / CC03
PFEESA< 0.003 µg/L0.003 µg/L2025-09-23DeKalb UD #1 Connection / CC04
PFHpA< 0.003 µg/L0.003 µg/L2025-09-23Gladeville Connection / CC02
PFHpS< 0.003 µg/L0.003 µg/L2025-09-23Lebanon Connection / CC01
PFHxA0.0034 µg/L0.003 µg/L2025-09-23Gladeville Connection / CC02
PFHxS< 0.003 µg/L0.003 µg/L2025-09-23DeKalb UD #1 Connection / CC04
PFMBA< 0.003 µg/L0.003 µg/L2025-09-23Consolidated UD Connection / CC03
PFMPA< 0.004 µg/L0.004 µg/L2025-09-23DeKalb UD #1 Connection / CC04
PFNA< 0.004 µg/L0.004 µg/L2025-09-23Lebanon Connection / CC01
PFOA0.0065 µg/L0.004 µg/L2025-09-23Consolidated UD Connection / CC03
PFOS< 0.004 µg/L0.004 µg/L2025-09-23Consolidated UD Connection / CC03
PFPeA0.0094 µg/L0.003 µg/L2025-09-23Consolidated UD Connection / CC03
PFPeS< 0.004 µg/L0.004 µg/L2025-09-23Lebanon Connection / CC01
PFTA< 0.008 µg/L0.008 µg/L2025-09-23DeKalb UD #1 Connection / CC04
PFTrDA< 0.007 µg/L0.007 µg/L2025-09-23DeKalb UD #1 Connection / CC04
PFUnA< 0.002 µg/L0.002 µg/L2025-09-23Consolidated UD Connection / CC03
lithium< 9 µg/L9 µg/L2025-09-23Lebanon Connection / CC01

Download all EPA UCMR 5 records (CSV)

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0.001 mg/L2023-01-01 – 2025-12-312026Q3
Lead (PB90) 0.001 mg/L2020-01-01 – 2022-12-312026Q3
Lead (PB90) 0.0005 mg/L2017-01-01 – 2019-12-312026Q3
Lead (PB90) 0.00104 mg/L2014-01-01 – 2016-12-312026Q3
Lead (PB90) 0.0005 mg/L2011-01-01 – 2013-12-312026Q3
Lead (PB90) 0.0024 mg/L2008-01-01 – 2010-12-312026Q3
Lead (PB90) 0.001 mg/L2005-01-01 – 2007-12-312026Q3
Lead (PB90) 0.0015 mg/L2002-01-01 – 2004-12-312026Q3

Published compliance history

4 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Twenty most recent imported compliance records
Rule / recordPeriodRecorded statusHealth-based (EPA classification)Source quarter
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2023-04-01 – 2023-06-30ResolvedYes2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2023-01-01 – 2023-03-31ResolvedYes2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2022-10-01 – 2022-12-31ResolvedYes2026Q3
Total Coliform Rule / Monitoring, Routine Minor (TCR)2002-09-01 – 2002-09-30ArchivedNo2026Q3

Source dates and refresh checks

A refresh check is not a sample date. Publication periods, sample dates and checks are shown separately.

Administrative contact (EPA filing)

Leauber, Chris: 615-449-2951

An administrative filing contact may not be a customer-service line. Confirm current contact details with the provider.