An independent public resourceEnglish Español

Avalon Subdivision

Published drinking-water records and contacts for Avalon Subdivision. System MT0004802. Review sources and dates; not a real-time water assessment.

System ID
MT0004802
State or territory
MT
Published population served
135
System type (source code)
CWS

Published records and dates

Missing records here do not mean the provider did not test. Published records are not a real-time assessment of your tap water.

Published testing results

Selected recent records are shown below. Different sampling locations and dates are not interchangeable. These excerpts are not a complete testing history.

“<” means below the stated reporting limit, not zero. A reported measurement alone is not a safety verdict. Read an example

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0.000444 mg/L2024-01-01 – 2026-12-312026Q3
Lead (PB90) 0.000484 mg/L2021-01-01 – 2023-12-312026Q3
Lead (PB90) 0 mg/L2020-01-01 – 2022-12-312026Q3
Lead (PB90) 0.008 mg/L2014-01-01 – 2016-12-312026Q3
Lead (PB90) 0.002 mg/L2013-07-01 – 2013-12-312026Q3
Lead (PB90) 0.01 mg/L2013-01-01 – 2013-06-302026Q3
Twelve most recent imported state laboratory records
SubstancePublished resultSample dateLocation / source
ARSENIC0.00342 mg/L2026-08-18EP502 / Montana selected chemical sample panels
BARIUM0.0227 mg/L2026-08-18EP502 / Montana selected chemical sample panels
CADMIUM< .0005 mg/L2026-08-18EP502 / Montana selected chemical sample panels
CHROMIUM0.000772 mg/L2026-08-18EP502 / Montana selected chemical sample panels
FLUORIDE< .021 mg/L2026-08-18EP502 / Montana selected chemical sample panels
MERCURY< .0001 mg/L2026-08-18EP502 / Montana selected chemical sample panels
NICKEL0.000489 mg/L2026-08-18EP502 / Montana selected chemical sample panels
NITRATE-NITRITE1.84 mg/L2026-08-18EP502 / Montana selected chemical sample panels
SELENIUM< .0005 mg/L2026-08-18EP502 / Montana selected chemical sample panels
ANTIMONY, TOTAL0.000138 mg/L2026-08-18EP502 / Montana selected chemical sample panels
BERYLLIUM, TOTAL< .0002 mg/L2026-08-18EP502 / Montana selected chemical sample panels
THALLIUM, TOTAL< .0001 mg/L2026-08-18EP502 / Montana selected chemical sample panels

State sampling points can include untreated water. Publisher qualifiers and units are retained; consult the full source notes before interpreting a record.

Download state records with source notes (CSV)

Published compliance history

20 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Twenty most recent imported compliance records
Rule / recordPeriodRecorded statusHealth-based (EPA classification)Source quarter
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2021-04-01 – 2021-04-30ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2021-03-01 – 2021-03-31ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2021-02-01 – 2021-02-28ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2021-01-01 – 2021-01-31ResolvedNo2026Q3
Lead and Copper Rule / Lead Consumer Notice2020-12-30 – —ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2020-12-01 – 2020-12-31ResolvedNo2026Q3
Consumer Confidence Rule / Consumer Confidence Report Inadequate Reporting2020-10-01 – —ResolvedNo2026Q3
Consumer Confidence Rule / Consumer Confidence Report Complete Failure to Report2020-07-01 – —ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2020-05-01 – 2020-05-31ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2020-04-01 – 2020-04-30ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2020-03-01 – 2020-03-31ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2020-02-01 – 2020-02-29ResolvedNo2026Q3
Inorganic Chemicals / Monitoring, Regular2020-01-01 – 2022-12-31ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2020-01-01 – 2020-01-31ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2019-12-01 – 2019-12-31ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2019-11-01 – 2019-11-30ResolvedNo2026Q3
Lead and Copper Rule / Follow-up Or Routine LCR Tap M/R2019-10-01 – —ResolvedNo2026Q3
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2019-09-01 – 2019-09-30ResolvedNo2026Q3
Consumer Confidence Rule / Consumer Confidence Report Complete Failure to Report2019-07-01 – —ResolvedNo2026Q3
Nitrate Rule / Monitoring, Regular2019-01-01 – 2019-12-31ResolvedNo2026Q3

Source dates and refresh checks

A refresh check is not a sample date. Publication periods, sample dates and checks are shown separately.

Administrative contact (EPA filing)

Utter, Kaylie: 406-581-5778

An administrative filing contact may not be a customer-service line. Confirm current contact details with the provider.

Official state resources · How to read these records