An independent public resourceEnglish Español

Maryland American Water Company

Published drinking-water records and contacts for Maryland American Water Company. System MD0120003. Review sources and dates; not a real-time water assessment.

System ID
MD0120003
State or territory
MD
Published population served
13200
System type (source code)
CWS

Published records and dates

Missing records here do not mean the provider did not test. Published records are not a real-time assessment of your tap water.

Published testing results

Selected recent records are shown below. Different sampling locations and dates are not interchangeable. These excerpts are not a complete testing history.

“<” means below the stated reporting limit, not zero. A reported measurement alone is not a safety verdict. Read an example

EPA UCMR 5 — most recent imported sample per substance
SubstancePublished resultReporting limitSample dateSampling location
11Cl-PF3OUdS< 0.005 µg/L0.005 µg/L2024-03-06Winters Run Filter Plant / 0100000
4:2 FTS< 0.003 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
6:2 FTS0.0072 µg/L0.005 µg/L2024-03-06Winters Run Filter Plant / 0100000
8:2 FTS< 0.005 µg/L0.005 µg/L2024-03-06Winters Run Filter Plant / 0100000
9Cl-PF3ONS< 0.002 µg/L0.002 µg/L2024-03-06Winters Run Filter Plant / 0100000
ADONA< 0.003 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
HFPO-DA< 0.005 µg/L0.005 µg/L2024-03-06Winters Run Filter Plant / 0100000
NEtFOSAA< 0.005 µg/L0.005 µg/L2024-03-06Winters Run Filter Plant / 0100000
NFDHA< 0.02 µg/L0.02 µg/L2024-03-06Winters Run Filter Plant / 0100000
NMeFOSAA< 0.006 µg/L0.006 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFBA< 0.005 µg/L0.005 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFBS< 0.003 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFDA< 0.003 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFDoA< 0.003 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFEESA< 0.003 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFHpA< 0.003 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFHpS< 0.003 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFHxA0.0048 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFHxS< 0.003 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFMBA< 0.003 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFMPA< 0.004 µg/L0.004 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFNA< 0.004 µg/L0.004 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFOA< 0.004 µg/L0.004 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFOS< 0.004 µg/L0.004 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFPeA< 0.003 µg/L0.003 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFPeS< 0.004 µg/L0.004 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFTA< 0.008 µg/L0.008 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFTrDA< 0.007 µg/L0.007 µg/L2024-03-06Winters Run Filter Plant / 0100000
PFUnA< 0.002 µg/L0.002 µg/L2024-03-06Winters Run Filter Plant / 0100000
lithium< 9 µg/L9 µg/L2024-03-06Winters Run Filter Plant / 0100000

Download all EPA UCMR 5 records (CSV)

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0.002 mg/L2021-01-01 – 2023-12-312026Q3
Lead (PB90) 0.001 mg/L2018-01-01 – 2020-12-312026Q3
Lead (PB90) 0.001 mg/L2015-01-01 – 2017-12-312026Q3
Lead (PB90) 0.002 mg/L2012-01-01 – 2014-12-312026Q3
Lead (PB90) 0.002 mg/L2009-01-01 – 2011-12-312026Q3
Lead (PB90) 0.003 mg/L2006-01-01 – 2008-12-312026Q3
Lead (PB90) 0.004 mg/L2003-01-01 – 2005-12-312026Q3
Lead (PB90) 0.002 mg/L2000-01-01 – 2002-12-312026Q3
Twelve most recent imported state laboratory records
SubstancePublished resultSample dateLocation / source
11Cl-PF3OUdSBelow a limit; numeric threshold unavailable ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4
9Cl-PF3ONSBelow a limit; numeric threshold unavailable ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4
ADONABelow a limit; numeric threshold unavailable ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4
HFPO-DABelow a limit; numeric threshold unavailable ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4
N-EtFOSAABelow a limit; numeric threshold unavailable ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4
N-MeFOSAABelow a limit; numeric threshold unavailable ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4
PFBS2.74 ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4
PFDABelow a limit; numeric threshold unavailable ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4
PFDoABelow a limit; numeric threshold unavailable ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4
PFHpA1.05 ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4
PFHxA2.19 ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4
PFHxS2.65 ppt2022-10-06WINTERS RUN FILTER PLANT / Maryland MDE PFAS study — Phase 4

State sampling points can include untreated water. Publisher qualifiers and units are retained; consult the full source notes before interpreting a record.

Download state records with source notes (CSV)

Published compliance history

0 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Source dates and refresh checks

A refresh check is not a sample date. Publication periods, sample dates and checks are shown separately.

Administrative contact (EPA filing)

Volk, Christian: 410-838-8404

An administrative filing contact may not be a customer-service line. Confirm current contact details with the provider.

Official state resources · How to read these records