An independent public resourceEnglish Español

Bayou Teche Water Works

Published drinking-water records and contacts for Bayou Teche Water Works. System LA1099002. Review sources and dates; not a real-time water assessment.

System ID
LA1099002
State or territory
LA
Published population served
10137
System type (source code)
CWS

Published records and dates

Missing records here do not mean the provider did not test. Published records are not a real-time assessment of your tap water.

Published testing results

Selected recent records are shown below. Different sampling locations and dates are not interchangeable. These excerpts are not a complete testing history.

“<” means below the stated reporting limit, not zero. A reported measurement alone is not a safety verdict. Read an example

EPA UCMR 5 — most recent imported sample per substance
SubstancePublished resultReporting limitSample dateSampling location
11Cl-PF3OUdS< 0.005 µg/L0.005 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
4:2 FTS< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
6:2 FTS< 0.005 µg/L0.005 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
8:2 FTS< 0.005 µg/L0.005 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
9Cl-PF3ONS< 0.002 µg/L0.002 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
ADONA< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
HFPO-DA< 0.005 µg/L0.005 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
NEtFOSAA< 0.005 µg/L0.005 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
NFDHA< 0.02 µg/L0.02 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
NMeFOSAA< 0.006 µg/L0.006 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFBA< 0.005 µg/L0.005 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFBS< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFDA< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFDoA< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFEESA< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFHpA< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFHpS< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFHxA< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFHxS< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFMBA< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFMPA< 0.004 µg/L0.004 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFNA< 0.004 µg/L0.004 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFOA< 0.004 µg/L0.004 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFOS< 0.004 µg/L0.004 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFPeA< 0.003 µg/L0.003 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFPeS< 0.004 µg/L0.004 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFTA< 0.008 µg/L0.008 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFTrDA< 0.007 µg/L0.007 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
PFUnA< 0.002 µg/L0.002 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ
lithium17.0 µg/L9 µg/L2023-10-16BAYOU TECHE WATER WORKS / 4AJJ

Download all EPA UCMR 5 records (CSV)

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0.003 mg/L2023-01-01 – 2025-12-312026Q3
Lead (PB90) 0.004 mg/L2020-01-01 – 2022-12-312026Q3
Lead (PB90) 0.001 mg/L2017-01-01 – 2019-12-312026Q3
Lead (PB90) 0.003 mg/L2014-01-01 – 2016-12-312026Q3
Lead (PB90) 0.003 mg/L2011-01-01 – 2013-12-312026Q3
Lead (PB90) 0.004 mg/L2005-01-01 – 2007-12-312026Q3
Lead (PB90) 0.006 mg/L2002-01-01 – 2004-12-312026Q3
Lead (PB90) 0.005 mg/L1999-01-01 – 2001-12-312026Q3

Published compliance history

10 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Twenty most recent imported compliance records
Rule / recordPeriodRecorded statusHealth-based (EPA classification)Source quarter
Consumer Confidence Rule / Consumer Confidence Report Complete Failure to Report2025-07-01 – —ResolvedNo2026Q3
Lead and Copper Rule Revisions / LSL Inventory2024-10-17 – —ResolvedYes2026Q3
Ground Water Rule / Failure To Address Deficiency2022-02-07 – —ResolvedYes2026Q3
Ground Water Rule / Failure To Address Deficiency2022-02-07 – —UnaddressedYes2026Q3
Ground Water Rule / Failure To Address Deficiency2022-02-07 – —ResolvedYes2026Q3
Ground Water Rule / Failure To Address Deficiency2022-02-07 – —ResolvedYes2026Q3
Stage 1 Disinfectants and Disinfection Byproducts Rule / Monitoring and Reporting (DBP)2018-04-01 – 2018-06-30ResolvedNo2026Q3
Lead and Copper Rule / Lead Consumer Notice2017-03-04 – —ResolvedNo2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Monthly (TCR)2004-10-01 – 2004-10-31ArchivedYes2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Monthly (TCR)1997-07-15 – 1997-08-14ArchivedYes2026Q3

Source dates and refresh checks

A refresh check is not a sample date. Publication periods, sample dates and checks are shown separately.

Administrative contact (EPA filing)

Bertrand Jr., Melvin: 337-319-6237

An administrative filing contact may not be a customer-service line. Confirm current contact details with the provider.

Official state resources · How to read these records