EPA UCMR 5 — most recent imported sample per substance
SubstancePublished resultReporting limitSample dateSampling location
11Cl-PF3OUdS< 0.005 µg/L0.005 µg/L2024-05-07Well #6 Treatment / 8MSX
4:2 FTS< 0.003 µg/L0.003 µg/L2024-05-07Well #7 Treatment / 8GFQ
6:2 FTS< 0.005 µg/L0.005 µg/L2024-05-07Well #7 Treatment / 8GFQ
8:2 FTS< 0.005 µg/L0.005 µg/L2024-05-07Well #6 Treatment / 8MSX
9Cl-PF3ONS< 0.002 µg/L0.002 µg/L2024-05-07Well #8 Treatment / 8MSY
ADONA< 0.003 µg/L0.003 µg/L2024-05-07Well #8 Treatment / 8MSY
HFPO-DA< 0.005 µg/L0.005 µg/L2024-05-07Well #7 Treatment / 8GFQ
NEtFOSAA< 0.005 µg/L0.005 µg/L2024-05-07Well #7 Treatment / 8GFQ
NFDHA< 0.02 µg/L0.02 µg/L2024-05-07Well #9 Treatment / 8GHQ
NMeFOSAA< 0.006 µg/L0.006 µg/L2024-05-07Well #8 Treatment / 8MSY
PFBA< 0.005 µg/L0.005 µg/L2024-05-07Well #9 Treatment / 8GHQ
PFBS< 0.003 µg/L0.003 µg/L2024-05-07Well #8 Treatment / 8MSY
PFDA< 0.003 µg/L0.003 µg/L2024-05-07Well #8 Treatment / 8MSY
PFDoA< 0.003 µg/L0.003 µg/L2024-05-07Well #9 Treatment / 8GHQ
PFEESA< 0.003 µg/L0.003 µg/L2024-05-07Well #8 Treatment / 8MSY
PFHpA< 0.003 µg/L0.003 µg/L2024-05-07Well #7 Treatment / 8GFQ
PFHpS< 0.003 µg/L0.003 µg/L2024-05-07Well #6 Treatment / 8MSX
PFHxA< 0.003 µg/L0.003 µg/L2024-05-07Well #9 Treatment / 8GHQ
PFHxS< 0.003 µg/L0.003 µg/L2024-05-07Well #7 Treatment / 8GFQ
PFMBA< 0.003 µg/L0.003 µg/L2024-05-07North Steel Ground Storage Tank #1 / 8AOZ
PFMPA< 0.004 µg/L0.004 µg/L2024-05-07North Steel Ground Storage Tank #1 / 8AOZ
PFNA< 0.004 µg/L0.004 µg/L2024-05-07Well #7 Treatment / 8GFQ
PFOA< 0.004 µg/L0.004 µg/L2024-05-07Well #7 Treatment / 8GFQ
PFOS< 0.004 µg/L0.004 µg/L2024-05-07North Steel Ground Storage Tank #1 / 8AOZ
PFPeA< 0.003 µg/L0.003 µg/L2024-05-07North Steel Ground Storage Tank #1 / 8AOZ
PFPeS< 0.004 µg/L0.004 µg/L2024-05-07North Steel Ground Storage Tank #1 / 8AOZ
PFTA< 0.008 µg/L0.008 µg/L2024-05-07Well #9 Treatment / 8GHQ
PFTrDA< 0.007 µg/L0.007 µg/L2024-05-07Well #8 Treatment / 8MSY
PFUnA< 0.002 µg/L0.002 µg/L2024-05-07Well #8 Treatment / 8MSY
lithium< 9 µg/L9 µg/L2024-05-07Well #7 Treatment / 8GFQ

Download all EPA UCMR 5 records (CSV)

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0.001 mg/L2024-01-01 – 2026-12-312026Q3
Lead (PB90) 0.001 mg/L2021-01-01 – 2023-12-312026Q3
Lead (PB90) 0.009 mg/L2018-01-01 – 2020-12-312026Q3
Lead (PB90) 0.002 mg/L2015-01-01 – 2017-12-312026Q3
Lead (PB90) 0.003 mg/L2012-01-01 – 2014-12-312026Q3
Lead (PB90) 0.006 mg/L2009-01-01 – 2011-12-312026Q3
Lead (PB90) 0.001 mg/L2008-01-01 – 2010-12-312026Q3
Lead (PB90) 0.000861 mg/L2005-01-01 – 2007-12-312026Q3

Published compliance history

15 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Twenty most recent imported compliance records
Rule / recordPeriodRecorded statusHealth-based (EPA classification)Source quarter
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2023-04-01 – 2023-06-30ResolvedYes2026Q3
Ground Water Rule / Failure To Address Deficiency2023-02-14 – —ResolvedYes2026Q3
Ground Water Rule / Failure To Address Deficiency2023-02-14 – —ResolvedYes2026Q3
Ground Water Rule / Failure To Address Deficiency2023-02-14 – —ResolvedYes2026Q3
Ground Water Rule / Failure To Address Deficiency2023-02-14 – —ResolvedYes2026Q3
Public Notice Rule and Revised PN Rule / Public Notification Violation for NPDWR Violation2020-04-15 – —ResolvedNo2026Q3
Ground Water Rule / Failure To Address Deficiency2020-02-24 – —ResolvedYes2026Q3
Ground Water Rule / Failure To Address Deficiency2020-02-24 – —ResolvedYes2026Q3
Ground Water Rule / Failure To Address Deficiency2020-02-24 – —ResolvedYes2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2017-07-01 – 2017-09-30ResolvedYes2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2017-04-01 – 2017-06-30ResolvedYes2026Q3
Stage 2 Disinfectants and Disinfection Byproducts Rule / Maximum Contaminant Level Violation, Average2017-01-01 – 2017-03-31ResolvedYes2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Acute (TCR)1995-12-15 – 1996-01-15ArchivedYes2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Monthly (TCR)1993-10-15 – 1993-11-14ArchivedYes2026Q3
Total Coliform Rule / Maximum Contaminant Level Violation, Monthly (TCR)1991-11-01 – 1991-11-30ArchivedYes2026Q3