An independent public resourceEnglish Español

University of Connecticut - Main Campus

Published drinking-water records and contacts for University of Connecticut - Main Campus. System CT0780021. Review sources and dates; not a real-time water assessment.

System ID
CT0780021
State or territory
CT
Published population served
27199
System type (source code)
CWS

Published records and dates

Missing records here do not mean the provider did not test. Published records are not a real-time assessment of your tap water.

Published testing results

Selected recent records are shown below. Different sampling locations and dates are not interchangeable. These excerpts are not a complete testing history.

“<” means below the stated reporting limit, not zero. A reported measurement alone is not a safety verdict. Read an example

EPA UCMR 5 — most recent imported sample per substance
SubstancePublished resultReporting limitSample dateSampling location
11Cl-PF3OUdS< 0.005 µg/L0.005 µg/L2024-06-21Connecticut Water Interconnect / EP002
4:2 FTS< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
6:2 FTS< 0.005 µg/L0.005 µg/L2024-06-21Connecticut Water Interconnect / EP002
8:2 FTS< 0.005 µg/L0.005 µg/L2024-06-21Connecticut Water Interconnect / EP002
9Cl-PF3ONS< 0.002 µg/L0.002 µg/L2024-06-21Connecticut Water Interconnect / EP002
ADONA< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
HFPO-DA< 0.005 µg/L0.005 µg/L2024-06-21Connecticut Water Interconnect / EP002
NEtFOSAA< 0.005 µg/L0.005 µg/L2024-06-21Connecticut Water Interconnect / EP002
NFDHA< 0.02 µg/L0.02 µg/L2024-06-21Connecticut Water Interconnect / EP002
NMeFOSAA< 0.006 µg/L0.006 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFBA< 0.005 µg/L0.005 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFBS< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFDA< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFDoA< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFEESA< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFHpA< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFHpS< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFHxA< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFHxS< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFMBA< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFMPA< 0.004 µg/L0.004 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFNA< 0.004 µg/L0.004 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFOA< 0.004 µg/L0.004 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFOS< 0.004 µg/L0.004 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFPeA< 0.003 µg/L0.003 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFPeS< 0.004 µg/L0.004 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFTA< 0.008 µg/L0.008 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFTrDA< 0.007 µg/L0.007 µg/L2024-06-21Connecticut Water Interconnect / EP002
PFUnA< 0.002 µg/L0.002 µg/L2024-06-21Connecticut Water Interconnect / EP002
lithium< 9 µg/L9 µg/L2024-06-21Connecticut Water Interconnect / EP002

Download all EPA UCMR 5 records (CSV)

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0.0076 mg/L2024-01-01 – 2026-12-312026Q3
Lead (PB90) 0.0007 mg/L2021-01-01 – 2023-12-312026Q3
Lead (PB90) 0 mg/L2018-01-01 – 2020-12-312026Q3
Lead (PB90) 0.0006 mg/L2015-01-01 – 2017-12-312026Q3
Lead (PB90) 0.011 mg/L2012-01-01 – 2014-12-312026Q3
Lead (PB90) 0.014 mg/L2009-01-01 – 2011-12-312026Q3
Lead (PB90) 0.0064 mg/L2006-01-01 – 2008-12-312026Q3
Lead (PB90) 0.0056 mg/L2003-01-01 – 2005-12-312026Q3

Published compliance history

3 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Twenty most recent imported compliance records
Rule / recordPeriodRecorded statusHealth-based (EPA classification)Source quarter
Revised Total Coliform Rule / Monitoring, Routine (RTCR)2017-09-01 – 2017-09-30ResolvedNo2026Q3
Stage 1 Disinfectants and Disinfection Byproducts Rule / Monitoring and Reporting (DBP)2017-07-01 – 2017-09-30ResolvedNo2026Q3
Consumer Confidence Rule / Consumer Confidence Report Complete Failure to Report2017-07-01 – —ResolvedNo2026Q3

Source dates and refresh checks

A refresh check is not a sample date. Publication periods, sample dates and checks are shown separately.

Administrative contact (EPA filing)

Nolan, Stanley: 860-486-3208

An administrative filing contact may not be a customer-service line. Confirm current contact details with the provider.

Official state resources · How to read these records