System ID
CA1010021
State or territory
CA
Published population served
11404
System type (source code)
CWS

Published records and dates

Missing records here do not mean the provider did not test. Published records are not a real-time assessment of your tap water.

Published testing results

Selected recent records are shown below. Different sampling locations and dates are not interchangeable. These excerpts are not a complete testing history.

“<” means below the stated reporting limit, not zero. A reported measurement alone is not a safety verdict. Read an example

EPA UCMR 5 — most recent imported sample per substance
SubstancePublished resultReporting limitSample dateSampling location
11Cl-PF3OUdS< 0.005 µg/L0.005 µg/L2024-07-23Mendota Water Plant / EP01
4:2 FTS< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
6:2 FTS< 0.005 µg/L0.005 µg/L2024-07-23Mendota Water Plant / EP01
8:2 FTS< 0.005 µg/L0.005 µg/L2024-07-23Mendota Water Plant / EP01
9Cl-PF3ONS< 0.002 µg/L0.002 µg/L2024-07-23Mendota Water Plant / EP01
ADONA< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
HFPO-DA< 0.005 µg/L0.005 µg/L2024-07-23Mendota Water Plant / EP01
NEtFOSAA< 0.005 µg/L0.005 µg/L2024-07-23Mendota Water Plant / EP01
NFDHA< 0.02 µg/L0.02 µg/L2024-07-23Mendota Water Plant / EP01
NMeFOSAA< 0.006 µg/L0.006 µg/L2024-07-23Mendota Water Plant / EP01
PFBA< 0.005 µg/L0.005 µg/L2024-07-23Mendota Water Plant / EP01
PFBS< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
PFDA< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
PFDoA< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
PFEESA< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
PFHpA< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
PFHpS< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
PFHxA< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
PFHxS< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
PFMBA< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
PFMPA< 0.004 µg/L0.004 µg/L2024-07-23Mendota Water Plant / EP01
PFNA< 0.004 µg/L0.004 µg/L2024-07-23Mendota Water Plant / EP01
PFOA< 0.004 µg/L0.004 µg/L2024-07-23Mendota Water Plant / EP01
PFOS< 0.004 µg/L0.004 µg/L2024-07-23Mendota Water Plant / EP01
PFPeA< 0.003 µg/L0.003 µg/L2024-07-23Mendota Water Plant / EP01
PFPeS< 0.004 µg/L0.004 µg/L2024-07-23Mendota Water Plant / EP01
PFTA< 0.008 µg/L0.008 µg/L2024-07-23Mendota Water Plant / EP01
PFTrDA< 0.007 µg/L0.007 µg/L2024-07-23Mendota Water Plant / EP01
PFUnA< 0.002 µg/L0.002 µg/L2024-07-23Mendota Water Plant / EP01
lithium< 9 µg/L9 µg/L2024-07-08Mendota Water Plant / EP01

Download all EPA UCMR 5 records (CSV)

Lead and copper: 90th-percentile summaries

These describe a monitoring period across sampled locations, not the result at your home. How to read the 90th percentile

Eight most recent imported monitoring summaries
SubstancePublished 90th percentileMonitoring periodSource quarter
Lead (PB90) 0 mg/L2022-01-01 – 2024-12-312026Q3
Lead (PB90) 0 mg/L2022-01-01 – 2024-12-312026Q3
Lead (PB90) 0 mg/L2019-01-01 – 2021-12-312026Q3
Lead (PB90) 0 mg/L2019-01-01 – 2021-12-312026Q3
Lead (PB90) 0 mg/L2016-01-01 – 2018-12-312026Q3
Lead (PB90) 0 mg/L2013-01-01 – 2015-12-312026Q3
Lead (PB90) 0 mg/L2010-01-01 – 2012-12-312026Q3
Lead (PB90) 0 mg/L2006-01-01 – 2008-12-312026Q3
Twelve most recent imported state laboratory records
SubstancePublished resultSample dateLocation / source
TDS540 MG/L2026-07-07COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results
IRON< 30.000000000 UG/L2026-07-07COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results
CONDUCTIVITY @ 25 C UMHOS/CM830 UMHO/CM2026-07-07COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results
TURBIDITY< 0.300000000 NTU2026-07-07COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results
MANGANESE< 10.000000000 UG/L2026-07-07COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results
IRON34 UG/L2026-06-30COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results
TURBIDITY< 0.300000000 NTU2026-06-30COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results
CONDUCTIVITY @ 25 C UMHOS/CM810 UMHO/CM2026-06-30COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results
TDS540 MG/L2026-06-30COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results
MANGANESE< 10.000000000 UG/L2026-06-30COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results
TURBIDITY< 0.300000000 NTU2026-06-23COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results
IRON< 30.000000000 UG/L2026-06-23COMBINED - FILTRATION PLANT EFFLUENT / California DDW laboratory results

State sampling points can include untreated water. Publisher qualifiers and units are retained; consult the full source notes before interpreting a record.

Download state records with source notes (CSV)

Published compliance history

0 imported records. Status is as recorded in the source; historical records are not current advisories. Missing records do not establish that no violations occurred.

Source dates and refresh checks

A refresh check is not a sample date. Publication periods, sample dates and checks are shown separately.

Administrative contact (EPA filing)

Gonzalez, Cristian: 559-655-3291

An administrative filing contact may not be a customer-service line. Confirm current contact details with the provider.

Official state resources · How to read these records